Temperature Controller For Fermentation Tank

Improving product quality: Temperature is a key factor influencing microbial metabolic pathways. Precise and stable temperature can ensure the efficient and consistent synthesis of products (such as antibiotics, enzymes, flavor substances), guaranteeing the stability of each batch of products. Increasing yield: Microorganisms grow and exhibit the highest metabolic activity at the optimal temperature. Precise temperature control can maximize the yield of target products, directly enhancing economic benefits.

  • Product Introduction

 

 

Temperature Controller for Fermentation Tank

Control temperature and pressure

Unambiguous and simple use

Mulit-level parametrizing, (access protected with passwords, which prevents "coincidental" changes)

Possibility of connecting into network (RS485)

Alarm for upper and lower limit

Simple assembly

Applied to food-processing field, esp. for temperature control in beer fermentation.

Temperature Controller for Fermentation Tank

Instruction

1. Instruction for state of light:

1. Cool light is on. It indicates the controller is in state of cooling and the cooling valve is on.

If the cool light flashes, the controller is in state of cooling while the cooling valve is off.

Pre. Light is on. It indicates the pressure valve is on. Otherwise the valve is off.

Setup Light is on. It indicates the controller is under setting state.

If ºC light on, it displays in celcius degree. ºF light on, it displays in Fahrenheit degree.

Alarm When the light flashes, it indicates temperature exceeds the limit or there is error in parameter.

2. Button [SET]

Press shortly and enter temperature setting.

Press long and enter parameter adjustment of program menu.

Button [▲], [▼] change set value.

2.Pressure control

When the pressure reaches the up limit, the pressure valve opens and Pre. light is on. When reaches the lower limit, the pressure valve shuts off and Pre. light is off.

 Alarm for false information:

-Er.S error in sensor

-Er.P error in program

When the above information appears, the controller will enter safe mode automatically.

3. Temperature setting

In normal display mode, press[SET] one minute and begin to the set temperature value. LED displays the set temperature and the light is on. Then press▲or▼to adjust temperature value. Press one time and the value will rise or fall 0.1C. Press ▲or▼ long, the set value will rise or fall quickly; afterwards press[SET] and withdraw from temperature setting.

 

Temperature Controller for Fermentation Tank

Parameter setting of controller:

Parameter setting of controller: level 1

Press[SET] three seconds or longer, LED displays"PAS". Release[SET], press▲▲▼▼ in turns and then press[SET] to confirm, thus enter parameter setting of controller 1.Press▲or▼ to choose parameter and press [SET] to confirm. Press End to exit parameter setting.

Table of parameter 1:

Parameter

Description

OFF

No display, cooling output is invalid and pressure output is valid

HEA

This mode is invalid

CoL

Cooling mode

H_C

Same to CoL

DiS

Temperature display,cooling output invalid and pressure output valid

 

Parameter setting of controller: level 2

Press[SET] three seconds or longer, LED displays"PAS". Release[SET], press▲▼▲▼ in turns and then press[SET] to confirm, thus enter parameter setting of controller 2:Press▲or▼ to choose parameter and press[SET]to confirm. Then press▲or▼to modify parameter, press SET to confirm.Press End to exit from parameter setting.

Table of parameter 2:

Parameter name

Range

Preset

Description

HSH

Heating hysteresis

0.1…20 after 0.1

1

invalid

HSC

Cooling hysteresis

0.1…20 after 0.1

1

When temperature value within the range, cooling output does not change status, and the mode does not change.

dbd

Dead zone

0.1…20 after 0.1

1

When the set value approaches this value, there is no cooling output or display state.

ALU

High temperature alarm point value

-9.9~99.9°C After0.1

14-212°F

After0.1

99.9°C

When exceeds this value, the controller alarms and the alarm light flashes.

ALd

Low temperature alarm point value

-9.9~99.9°C

After0.1

14-211°F

After0.1

-9.9°C

When lower than this value, the controller alarms and the alarm light flashes.

 

Parameter setting of controller: level 3

Press[SET] three seconds or longer, LED displays"PAS". Release[SET], press▼▼▲▲▲ in turns and then press[SET] to confirm,thus enter parameter setting of controller 3.Press▲or▼to choose tSt and pressSET to confirm.Then press▲or▼to choose Ini and press[SET] to confirm.LED displays"--―"and parameter restore.Then press▲or▼and choose End,press SET to confirm and exit from parameter setting.

Table of parameter 3:

Parameter name

Range

Preset

Description

TPU

Option of temperature measure unit C/F

CEL

FAH

CEL

Measure unit: celsius degree or fahrenheit degreeC/F

Flt

Input filtering

0 to 60 vz.

5 vz.

Display the rise degree of this value

SAF

Safe mode

noA

CoL

HEA

noA

Enter safe mode in the following condition

noA...cooling output invalid; pressure output valid

CoL... cooling output invalid

HEA invalid

coA

Communication address

1 to 999

1

Controller address code No.

tSt

Test calibration select

InI

EE

Cor

End

InI

Restore the set value

EE.....eprom test

Cor .temperature adjust value

End...exit menu operation

Cot

Open time of cooling valve

0~999分钟

10

Open time of valve during cooling process

Clt

Shut time of cooling valve

0~999分钟

10

Shut time of valve during cooling process

Product Manufacture

 

137
Temperature Controller for Fermentation Tank
139

 

Packing and Delivery

 

Temperature Controller for Fermentation Tank

 

Certificate

Temperature Controller for Fermentation Tank

Customer Review

 

 

Temperature Controller for Fermentation Tank

Hot Tags: temperature controller for fermentation tank, China temperature controller for fermentation tank manufacturers, suppliers, factory, Brewery Plc Control Cabinet, Single Tank Temperature Controller

Send Inquiry

(0/10)

clearall